Standards Matrix
| Domain | Standard | Status |
|---|---|---|
| Quality management | IATF 16949 | Certified |
| Functional safety | ISO 26262 | ASIL per control loop, documented |
| Cyber security | ISO/SAE 21434 | Designed to |
| AC charging | IEC 61851-1 | Compliant |
| AC connector | IEC 62196-2 (Type 2), SAE J1772 (Type 1) | Compliant |
| DC connector | IEC 62196-3 (CCS1 / CCS2) | Compliant |
| Digital communication | ISO 15118-2 / -20, DIN 70121 | Compliant, PnC optional |
| GB/T | GB/T 18487, GB/T 20234, GB/T 27930 | Compliant |
| EMC — emissions | CISPR 25, EN 61000-6-3 | Tested |
| EMC — immunity | ISO 11452, EN 61000-6-2 | Tested |
| Vehicle EMC | UNECE R10 | Designed to, per platform statement |
| Ingress protection | IEC 60529 (IP67 / IP6K9K) | Tested |
| Vibration | ISO 16750-3, QC/T 895 | Tested |
| Process | ASPICE | Level 2, in assessment |
Status is stated per platform. Request the platform specific statement in the download centre or through the enquiry form.