Charging Cables

Home  /  Products  /  Charging Cables

Products

Charging Cables

AC and DC charging cables with TPU or TPE jackets, straight or coiled, with liquid-cooled construction for high-current DC duty.

  • Conductor: 2.5 – 120 mm²
  • Jacket: TPU · TPE
  • Construction: Straight · coiled · liquid-cooled
  • Standards: IEC 62196 · GB/T 20234
  • Shielding: Shielded or unshielded
  • Ingress rating: IP55 with fitted coupler

Key benefits

Cooling designed with the coupler

The thermal path runs continuously from contact to cable, so the derating curve is a property of the assembly rather than two independently rated parts.

Cold-flex behaviour specified

Jacket compounds are chosen for low-temperature flexibility, which is where cheap cables fail first in northern European and North American winters.

Shielding where the vehicle needs it

Shielded and unshielded constructions are both available, selected against the EMC concept of the platform rather than by default.

Description

The cable is the part of a charging system that takes the most physical abuse and is the most visible to the end user. Jacket material, bend radius and cold-flex behaviour matter more to real-world durability than the conductor rating does.

Liquid-cooled DC cables carry the coolant alongside the conductors, which is what allows 500 A through a cable an operator can lift. Cooling loop integration is designed together with the coupler so the thermal path is continuous.

Technical specifications

Parameter Value / Condition
Conductor cross-section 2.5 mm² – 120 mm²
Jacket material TPU or TPE
Construction Straight, coiled, or liquid-cooled
Shielding Shielded or unshielded
Rated voltage Up to 1,000 V DC
Rated current Up to 500 A liquid-cooled
Lengths Standard 3 m / 5 m / 7 m, custom on request

Configuration options

Type Cross-section Max current Cooling Typical use
AC, straight 2.5 – 6 mm² 32 A Natural Portable AC
AC, coiled 2.5 – 6 mm² 32 A Natural On-board stowage
DC, natural 25 – 70 mm² 200 A Natural Public DC
DC, liquid-cooled 35 – 120 mm² 500 A Liquid High-power DC
Parameter Value / Condition
Operating temperature -30 °C to +50 °C (mobile), -40 °C to +85 °C (fixed)
Parameter Value / Condition
Standards IEC 62196 · GB/T 20234

.grap-panel{display:block !important;}

Applications

  • Public charging
  • Workplace charging
  • Fleet depots
  • Portable emergency chargers
  • Wallbox

FAQ

TPU or TPE?

TPU has better abrasion and cut resistance; TPE is lighter and more flexible in the cold. For public duty we normally recommend TPU.

When is liquid cooling worth it?

Above roughly 300 A. Below that the weight and cost of the cooling loop is not justified by the conductor saving.

Downloads

Cable datasheets and construction drawings
Conductor, jacket, shielding and derating data.

Open download centre

Related resources

Related products